PFK-105电离测试仪
测试和平衡电离器的完美工具
●用于测量偏移电压和放电时间的电离测试套件
●包括现场仪表、充电板监测器、±1000伏充电器和衰变计时器
●根据ANSI/ESD SP3平衡电离器。3.定期核查
●测量身体电压的产生和衰减
●评估电离器和包装材料
●包括一个将PFM-711B、CPM-720B和PDT-740B固定为一体的夹具
●模压车壳,内含泡沫衬垫
Ionization Test Kit for Measuring Offset Voltage and DischargeTimes
Includes a Field Meter, Charge Plate Monitor, ±1000 Volt Chargerand Decay Timer
Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification
Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESDSP3.3.
Measure Body Voltage Generation and Decay
evaluate Ionizers and Packaging Materials
Includes a fixture to hold the PFM-711B, CPM-720B and PDT-740Bas one
Molded Carying Case with Foam Insert Included
测量偏移电压和电荷衰减
PFK-105电离测试套件是一个方便的套件,包括PFM-711B现场仪表、CPM-720B充电板监测器、PCS-730B±1kV充电器和PDT-740B静态衰减计时器,用于测量使用区域内电离器的性能。该套件包括一个轻巧的夹具,可以将现场仪表、充电板和衰变计时器组合成一个手持式装置,
从而更容易测量电离器的偏移电压和放电时间。
静电场测试仪
手持式PFM-711B野外测量仪是一种用于在环境条件下(23ºC和30%Rh)对物体进行静态测量和极性测量的仪器,精度为±5%。这种稳定的斩波器可以在存在电离的环境中使用,而不会漂移。Hold(保持)按钮允许现场仪表保持测量,以便于记录。它还具有自动极性指示、低电量
指示灯、高量程和低量程、用于和可重复测量的测距灯、零位控制按钮和接地卡。PFM-711B包括两个操作范围:
0至1999V,1伏增量,误差<±5%
0至20000V,10伏增量,误差小于±5%,上限为5kV
PFM-711B可与X-Y绘图仪、任何模拟数据记录设备或PGA-710B自动分析系统一起使用。模拟输出提供对应于10kV的1V输出,与所选仪表范围和指示无关。
电荷板监视器允许你测量电离器
CPM-720B充电板监测器是一个连接到PFM-711B现场仪表的导电板。连接后,系统将允许按照ANSI/ESDSP3平衡电离器。3、电压或电荷产生和电压抑制分析。
施加±1000伏的电荷
PCS-730B±1 kV静电充电器用于将CPM-720B充电板监测器充电至±1000伏,以测量ANSI/ESDS3要求的电离器衰减时间。1和ANSI/ESD SP3。3.
PFM-711B现场仪表、CPM-720B充电板监测器和PCS-730B充电源经过匹配校准,可协同工作,实现准确高效的审计。
测量衰变时间
PDT-740B静态衰变计时器是Prostat创新技术的典型代表,并为专门ESD控制经理和审计员提供支持。
根据ESD协会的电离标准ANSI/ESDS3,这种独特的附件设计用于测量电离器从±1000伏到小于100伏的衰减时间。1,并测量小于50伏和小于10伏的材料衰减时间。
电离器分析的帮手!
PFK-100H夹具设计用于轻松固定PFM-711B野外测量仪、CPM-720B充电板监视器和PDT-740B静态衰减计时器。该仪器支架重量轻,一只手握住所有仪器,有助于平衡电离器。
符合ANSI/ESD标准
PFK-105将根据以下ESD协会文件评估电离器的性能规范:
ESD TR53
ANSI/ESD S3.1
ANSI/ESD SP3.3
ANSI/ESD S20.20
Measures Offset Voltage andCharge Decay
The PFK-105 Ionization Test Kit is a convenient kit that includesthe PFM-711B Field Meter, CPM-720B Charge Plate Monitor, thePCS-730B ±1 kV Charger and PDT-740B Static Decay Timer formeasuring the perofrmance of ionizers in the area of use. Includedwith the kit a lightweight fixture allowing to combine the FieldMeter, Charge Plate and Decay Timer into one hand-held unit, makingit easier to measure the offset voltage and discharge times of yourionizers.
Meter for Testing ofElectrostatic Fields
The hand-held PFM-711B Fieldmeter is an instrument used to performstatic surveys and polarity on objects with accuracy of ±5% atambient conditions (23ºC and 30%Rh). This stabilized chopper can beused in environments with a presence of ionization withoutdrifting. The Hold button allows the field meter to hold themeasurement for easy recording. It also features automatic polarityindication, low battery indicator, high and low ranges, distanceranging lights for accurate and repeatable measurements, a Zerocontrol button and a ground snap. The PFM-711B includes two rangesof operation:
0 to 1,999V in 1 Volt increments with <±5% error
0 to 20,000V in 10 Volt increments with <±5% error up to5kV
The PFM-711B can be used with a X-Y plotter, any analogdata-recording devices, or the PGA-710B Autoanalysis System. Theanalog output provides a 1 volt output corresponding to 10kV, whichis independent of the selected meter range and indication.
Charge Plate Monitorallowing you to Measure Ionizers
The CPM-720B Charge Plate Monitor is a conductive plate thatattaches to the PFM-711B Field Meter. When attached, the systemwill allow to balance ionizers per ANSI/ESD SP3.3, voltage orcharge generation and voltage suppression analysis.
Apply a Charge of ±1,000volts
The PCS-730B ±1 kV Electrostatic Charger is used to charge theCPM-720B Charge Plate Monitor to ±1,000 volts to measure ionizerdecay time as required by both ANSI/ESD S3.1 and ANSI/ESDSP3.3.
The PFM-711B Field Meter, the CPM-720B Charge Plate Monitor and thePCS-730B Charging Source are match calibrated to work together foraccurate and efficient auditing.
Measuring DecayTime
The PDT-740B Static Decay Timer is typical of Prostat’s innovativetechnology and support of professional ESD control managers andauditors.
This unique accessory is designed to measure the decay time ofionizers from ±1,000 volts to less than 100 volts in accordancewith ESD Association’s Ionization Standard ANSI/ESD S3.1, andmeasure material decay time to less than 50 volts and less than 10volts.
A Helping Hand for IonizerAnalysis!
The PFK-100H fixture is designed to easily hold your PFM-711B FieldMeter, your CPM-720B Charge Plate Monitor and your PDT-740B StaticDecay Timer. Lightweight, this instrument holder will facilitatebalancing your ionizer, by holding all instruments in 1 hand.
Complies to ANSI/ESDStandards
The PFK-105 will assess the performance specifications of ionizersin accordance with the following ESD Association documents:
ESD TR53
ANSI/ESD S3.1
ANSI/ESD SP3.3
ANSI/ESD S20.20